Temporary removal of vertical bracing - Structural engineering general discussion (2024)

  • Home
  • Forums
  • People
  • Structural Engineers
  • Structural engineering general discussion
  • Thread starterAmr Abdelhalim
  • Start dateJul 24, 2022
Status
Not open for further replies.
  • Jul 24, 2022
  • #1

Amr Abdelhalim

Structural
May 12, 2019
12

There is an existing steel pipe rack which there are 3 levels of vertical bracing.

The lower level of one direction vertical bracing in one span have to be removed temporarily for one week to allow a crane to enter to do a job there, is it safe to do so? No wind speed there and it is hard to re-evaluate the original calculation design.

Replies continue below

Recommended for you

Sort by dateSort by votes

  • Jul 24, 2022
  • #2

JLNJ

Structural
Oct 26, 2006
1,986

It sounds like you need to hire a structural engineer to do some calculations. It should be pretty simple to evaluate.

Upvote0Downvote

  • Jul 24, 2022
  • #3

dik

Structural
Apr 13, 2001
25,697

You should provide alternate bracing while you do the work.

So strange to see the singularity approaching while the entire planet is rapidly turning into a hellscape. -John Coates

-Dik

Upvote0Downvote

  • Jul 24, 2022
  • #5

271828

Structural
Mar 7, 2007
2,249

A structural engineer needs to be evaluate this situation. I'm aware of project in which a structure had lateral bracing removed and collapsed with multiple fatalities.

No wind. It seems to have experienced story buckling.

Upvote0Downvote

  • Jul 25, 2022
  • #6

LittleInch

Petroleum
Mar 27, 2013
21,379

Is the bracing asking the line of the rack or across the line.

A drawing would help but you have a lot of other forces in a rack than just wind.

Forces from the pipes are a major element as well as thermal expansion of the rack itself.

Remember - More details = better answers
Also: If you get a response it's polite to respond to it.

Upvote0Downvote

  • Jul 25, 2022
  • Thread starter
  • #7

Amr Abdelhalim

Structural
May 12, 2019
12

I attach a drawing with highlighted the required bracing to be removed

Temporary removal of vertical bracing - Structural engineering general discussion (8)

Upvote0Downvote

  • Jul 25, 2022
  • #8

LittleInch

Petroleum
Mar 27, 2013
21,379

So this is a cross section along the rack? Or a longitudinal part picture?

I'm guessing a cross section as the TOS levels vary. What spacing are the columns? Is it just one bay you're taking out or several?

Is there room to add a bracing to right and left of the red circle? I.e. move your removed bracing a few metres right and left?

How wide a gap in the section do you need? Can you install temporary vertical supports either side of the gap you need for the crane?

Plenty to think about for the structural engineer....

Remember - More details = better answers
Also: If you get a response it's polite to respond to it.

Upvote0Downvote

  • Jul 25, 2022
  • Thread starter
  • #9

This is a cross section along the rack however this bay is unique.

The spacing is 5.70 m and I am talking about this bay only.

Shifting bracing will be difficult to execute.

My question was preliminary as a concept, I shall create a model for the structure and re-evaluate the members before and after removing the required bracing.

Upvote0Downvote

  • Jul 25, 2022
  • #10

LittleInch

Petroleum
Mar 27, 2013
21,379

So are the bays free standing on does this bay share a vertical member between it and the bay to the left?

How big a hole do you need for the crane? Presumably less than 4 m high, but how wide? Could you put slightly bigger knee braces in at the corner?

Remember - More details = better answers
Also: If you get a response it's polite to respond to it.

Upvote0Downvote

  • Jul 25, 2022
  • #11

le99

Civil/Environmental
Jan 23, 2022
380

I don't see the temporary removal of bracing will cause much problem. You should consider vacating the level immediately above too.

Upvote0Downvote

  • Jul 25, 2022
  • #12

JoshPlumSE

Structural
Aug 15, 2008
9,653

I believe there is an ASCE guideline or code for temporary structures. Frequently used for concrete forming and construction related issues. It gives some guidance as to what level of lateral loads need to considered.

It is likely (IMO) that you will not need any temporary bracing as there are 3 other brace frames in the direction of the removed braces. However, it would be a good idea to obtain a copy of that code/guideline to justify it.

Upvote0Downvote

  • Jul 25, 2022
  • #13

Lomarandil

Structural
Jun 10, 2014
1,877

Josh is referring to ASCE 37. It's set up for North America, but should be generally applicable to most conditions in low-seismic countries like Egypt.

----
just call me Lo.

Upvote0Downvote

Status
Not open for further replies.

Similar threads

  • Question

Temporary Propping - Factor of Safety for Loads

  • Aytacoglu
  • Nov 3, 2024
  • Structural engineering general discussion
Replies
8
Views
3K

Nov 5, 2024

phuduhudu

  • Locked
  • Question

Vertical Bracing Line at Roof Expansion Joint

  • pioneer09
  • May 30, 2024
  • Structural engineering general discussion
Replies
1
Views
103

May 30, 2024

KootK

  • Locked
  • Question

Temporary Fencing Requirements

  • Ambemily
  • Sep 11, 2024
  • Structural engineering general discussion
Replies
3
Views
99

Sep 17, 2024

bridgebuster

  • Question

CFS Stud Bracing Confusion

  • StrEng007
  • Nov 8, 2024
  • Structural engineering general discussion
Replies
14
Views
3K

Nov 10, 2024

human909

  • Locked
  • Question

Temporary Support for Rebar Cage

  • e104909
  • Sep 26, 2024
  • Structural engineering general discussion
Replies
0
Views
267

Sep 26, 2024

e104909

Part and Inventory Search

Sponsor

  • Home
  • Forums
  • People
  • Structural Engineers
  • Structural engineering general discussion
Temporary removal of vertical bracing - Structural engineering general discussion (2024)
Top Articles
Latest Posts
Recommended Articles
Article information

Author: Horacio Brakus JD

Last Updated:

Views: 5446

Rating: 4 / 5 (71 voted)

Reviews: 86% of readers found this page helpful

Author information

Name: Horacio Brakus JD

Birthday: 1999-08-21

Address: Apt. 524 43384 Minnie Prairie, South Edda, MA 62804

Phone: +5931039998219

Job: Sales Strategist

Hobby: Sculling, Kitesurfing, Orienteering, Painting, Computer programming, Creative writing, Scuba diving

Introduction: My name is Horacio Brakus JD, I am a lively, splendid, jolly, vivacious, vast, cheerful, agreeable person who loves writing and wants to share my knowledge and understanding with you.